NONPRODUCTION / CONTROLLED UAT · PROFESSIONAL VALIDATION REQUIRED

PV-CT-MEAS-001

Software PASS
Units:
Account

Software verification and independent professional review are tracked separately. This page never claims professional approval — only a qualified reviewer, using their own judgement, credentials, and the reviewer packet below, can determine whether a case is acceptable.

CT measured-scatter comparison

v1.0.0 · ct
Purpose
Compare predicted CT scatter point to a synthetic measured value.
Required reviewer qualification
Diagnostic medical physicist or qualified expert
Formula IDs
CT.SCATTER.POINT
Dataset binding
METADATA_CITATION_ONLY

Assumptions

  • Synthetic measured fixture for software workflow only

Applicability limits

  • Measured-vs-predicted workflows

Known limitations

  • Measured value is synthetic; not a field survey

Independent calculation instructions: Enter an independent measured scatter and compare ratio to prediction.

Software results

Compared against a locked regression baseline. Comparison state: PASS · Verification state: SOFTWARE_VERIFICATION_PASS

Software result values
FieldValue
predictedMgy0.005000
measuredMgy0.006000
ratio1.200000

Input hash: 052ee4602c5cf5dc · Result hash: a0af861396561e98

Reviewer packet

Full markdown packet a qualified reviewer uses to perform an independent calculation.

# Reviewer packet — PV-CT-MEAS-001

**Title:** CT measured-scatter comparison
**Version:** 1.0.0
**Modality:** ct
**Software state:** SOFTWARE_VERIFICATION_PASS
**Independent review status:** READY_FOR_INDEPENDENT_REVIEW (pending human entry)

## Boundaries

- Software verification is not professional validation.
- Self-review does not qualify as independent review.
- Do not fabricate independent results.
- Licensed package citation: `ncrp147-diagnostic-uat-0.3.0` (METADATA_CITATION_ONLY).
- Numeric software lock uses demonstration transmission parameters only.

## Purpose

Compare predicted CT scatter point to a synthetic measured value.

## Formula IDs

- `CT.SCATTER.POINT`

## Independent calculation instructions

Enter an independent measured scatter and compare ratio to prediction.

## Required reviewer qualification

Diagnostic medical physicist or qualified expert

## Software results (comparison values; not pre-rounded away)

```json
{
  "predictedMgy": 0.005,
  "measuredMgy": 0.006,
  "ratio": 1.2
}
```

## Display rounding (informational only)

```json
{
  "predictedMgy": "0.005000",
  "measuredMgy": "0.006000",
  "ratio": "1.200000"
}
```

## Hashes

- Input hash: `052ee4602c5cf5dc`
- Result hash: `a0af861396561e98`

## Assumptions

- Synthetic measured fixture for software workflow only

## Known limitations

- Measured value is synthetic; not a field survey

Independent result entry

Demo-only entry for this CONTROLLED_UAT session. Values are held in server memory (not a database) and reset when the server restarts.

SYNTHETIC / DEMO ENTRY — not a real independent professional review

Independently computed values

Discrepancies

No discrepancies opened for this case.

Professional approval attempt

Approval is blocked while any discrepancy is open, while the case has not passed software verification, when no independent result has been recorded, or when credential/authority requirements are not met. Any approval recorded in this environment is a CONTROLLED UAT ELECTRONIC APPROVAL RECORD — not a qualified digital signature — and does not itself constitute professional approval.