Future workload scenario

v1.0.0 · mixed
Purpose
Compare current vs future weekly dose scenarios.
Required reviewer qualification
Diagnostic medical physicist or qualified expert
Formula IDs
CT.SCENARIO.COMPARISON
Dataset binding
METADATA_CITATION_ONLY

Assumptions

  • Future workload +30%

Applicability limits

  • Scenario planning

Known limitations

  • Scenario doses are precomputed inputs

Independent calculation instructions: Confirm both scenarios meet the design goal and compute delta.

Software results

Compared against a locked regression baseline. Comparison state: PASS · Verification state: SOFTWARE_VERIFICATION_PASS

Software result values
FieldValue
currentWeeklyMgy0.050000
futureWeeklyMgy0.065000
bothMeetGoaltrue

Input hash: a5c33c69053cd1c4 · Result hash: 5a084f6155e0f7a8

Reviewer packet

Full markdown packet a qualified reviewer uses to perform an independent calculation.

# Reviewer packet — PV-RAD-FUT-001

**Title:** Future workload scenario
**Version:** 1.0.0
**Modality:** mixed
**Software state:** SOFTWARE_VERIFICATION_PASS
**Independent review status:** READY_FOR_INDEPENDENT_REVIEW (pending human entry)

## Boundaries

- Software verification is not professional validation.
- Self-review does not qualify as independent review.
- Do not fabricate independent results.
- Licensed package citation: `ncrp147-diagnostic-uat-0.3.0` (METADATA_CITATION_ONLY).
- Numeric software lock uses demonstration transmission parameters only.

## Purpose

Compare current vs future weekly dose scenarios.

## Formula IDs

- `CT.SCENARIO.COMPARISON`

## Independent calculation instructions

Confirm both scenarios meet the design goal and compute delta.

## Required reviewer qualification

Diagnostic medical physicist or qualified expert

## Software results (comparison values; not pre-rounded away)

```json
{
  "currentWeeklyMgy": 0.05,
  "futureWeeklyMgy": 0.065,
  "bothMeetGoal": true
}
```

## Display rounding (informational only)

```json
{
  "currentWeeklyMgy": "0.050000",
  "futureWeeklyMgy": "0.065000",
  "bothMeetGoal": "true"
}
```

## Hashes

- Input hash: `a5c33c69053cd1c4`
- Result hash: `5a084f6155e0f7a8`

## Assumptions

- Future workload +30%

## Known limitations

- Scenario doses are precomputed inputs

Independent result entry

Demo-only entry for this CONTROLLED_UAT session. Values are held in server memory (not a database) and reset when the server restarts.

SYNTHETIC / DEMO ENTRY — not a real independent professional review

Independently computed values

Discrepancies

No discrepancies opened for this case.

Professional approval attempt

Approval is blocked while any discrepancy is open, while the case has not passed software verification, when no independent result has been recorded, or when credential/authority requirements are not met. Any approval recorded in this environment is a CONTROLLED UAT ELECTRONIC APPROVAL RECORD — not a qualified digital signature — and does not itself constitute professional approval.