PV-RAD-WINDOW-001

Software PASS
Units:
Account

Software verification and independent professional review are tracked separately. This page never claims professional approval — only a qualified reviewer, using their own judgement, credentials, and the reviewer packet below, can determine whether a case is acceptable.

Lead-glass window

v1.0.0 · radiography
Purpose
Window receptor path software check.
Required reviewer qualification
Diagnostic medical physicist or qualified expert
Formula IDs
RAD.SECONDARY.SCATTER
Dataset binding
METADATA_CITATION_ONLY

Assumptions

  • Window attenuation represented by thickness

Applicability limits

  • Lead-glass windows

Known limitations

  • Optical lead equivalence not manufacturer-specific

Independent calculation instructions: Evaluate window path weekly scatter at 2.0 m.

Software results

Compared against a locked regression baseline. Comparison state: PASS · Verification state: SOFTWARE_VERIFICATION_PASS

Software result values
FieldValue
weeklyScatterMgy0.000737
assemblyDistanceM2.000000

Input hash: 9407fa0dd8a972d7 · Result hash: 50a4c7a2443867ab

Reviewer packet

Full markdown packet a qualified reviewer uses to perform an independent calculation.

# Reviewer packet — PV-RAD-WINDOW-001

**Title:** Lead-glass window
**Version:** 1.0.0
**Modality:** radiography
**Software state:** SOFTWARE_VERIFICATION_PASS
**Independent review status:** READY_FOR_INDEPENDENT_REVIEW (pending human entry)

## Boundaries

- Software verification is not professional validation.
- Self-review does not qualify as independent review.
- Do not fabricate independent results.
- Licensed package citation: `ncrp147-diagnostic-uat-0.3.0` (METADATA_CITATION_ONLY).
- Numeric software lock uses demonstration transmission parameters only.

## Purpose

Window receptor path software check.

## Formula IDs

- `RAD.SECONDARY.SCATTER`

## Independent calculation instructions

Evaluate window path weekly scatter at 2.0 m.

## Required reviewer qualification

Diagnostic medical physicist or qualified expert

## Software results (comparison values; not pre-rounded away)

```json
{
  "weeklyScatterMgy": 0.0007370612308419333,
  "assemblyDistanceM": 2
}
```

## Display rounding (informational only)

```json
{
  "weeklyScatterMgy": "0.000737",
  "assemblyDistanceM": "2.000000"
}
```

## Hashes

- Input hash: `9407fa0dd8a972d7`
- Result hash: `50a4c7a2443867ab`

## Assumptions

- Window attenuation represented by thickness

## Known limitations

- Optical lead equivalence not manufacturer-specific

Independent result entry

Demo-only entry for this CONTROLLED_UAT session. Values are held in server memory (not a database) and reset when the server restarts.

SYNTHETIC / DEMO ENTRY — not a real independent professional review

Independently computed values

Discrepancies

No discrepancies opened for this case.

Professional approval attempt

Approval is blocked while any discrepancy is open, while the case has not passed software verification, when no independent result has been recorded, or when credential/authority requirements are not met. Any approval recorded in this environment is a CONTROLLED UAT ELECTRONIC APPROVAL RECORD — not a qualified digital signature — and does not itself constitute professional approval.